Vitamins A and E in Serum/Plasma - HPLC Basic Kit

Order No.: 34400-BK
Parameters:
Vitamin A, Vitamin E

Short run time of less than 3 min
Easy sample preparation
High eluate stability

Assay validated according to IVDR (=> Declaration of Conformity)

Vitamin A

Vitamin E

Clinical relevance
This assay allows the quantitative determination of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III in human urine samples.
It is intended to be used for patients in whom the urinary levels of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III are of clinical importance, primarily as an aid to diagnosis of suspected acute intermittent porphyria, porphyria variegata, aminolevulinic acid dehydratase deficiency porphyria, hereditary coproporphyria, porphyria cutanea tarda or congenital erythropoietic porphyria and/or for their differential diagnosis.


Product advantages
• Easy sample preparation
• Stable standards and controls


Assay characteristics
Sample preparation consists of sample stabilisation, addition of the internal standard followed by centrifugation to separate particles that may be present in the urine. An oxidation step is not necessary as the porphyrinogens oxidise spontaneously by air into the fluorescent porphyrins. The internal standard elutes between the analytes thus avoiding analytical variation and inaccuracy as well as allowing a shortening of the chromatographic run time.

Detailed performance evaluation data for this assay can be found in Appendices II and III of the instruction manual.


Two types of kits available

Basic Kit
• Only sample preparation reagents and vials included
• No excess quantities of mobile phase and calibrators

34400-BK Basic Kit
For 200 sample preparations

   
   
34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (2x)

Reagent Kit
• Mobile phase and calibrator included

34400 Reagent Kit
For 200 tests

34001 Mobile Phase, 1000 ml (1x)
34004 Serum Calibration Standard, 5 x 1 ml (lyoph.) (1x)
34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (2x)
More Information
Method of Analysis HPLC
Sample Preparations 200
Please note The information listed here, including the sample preparation, is not sufficient for using the product. Please read the information provided in the instruction manual, which includes detailed information on limitations associated with the use of the product in line with its intended purpose. Detailed performance evaluation data for this assay can be found in Appendices II and III of the instruction manual.
Lower and Upper Limit of Quantitation

Uroporphyrin: 0.48 µg/l – 1400 µg/l
Heptacarboxyporphyrin: 0.84 µg/l – 3200 µg/l
Hexacarboxyporphyrin: 1.8 µg/l – 5000 µg/l
Pentacarboxyporphyrin: 0.90 µg/l – 4600 µg/l
Coproporphyrin I: 2.2 µg/l – 5000 µg/l
Coproporphyrin III: 2.6 µg/l – 5000 µg/l

Different systems might show different performance data.

Specimen Urine
Sample Preparation

The information on the sample preparation presented here is not sufficient for use in the laboratory. For a detailed step by step description, please refer to the instruction manual.

  • Pipette 500 µl sample/calibrator/control into an amber reaction vial.
  • Add 50 µl Stabilisation Reagent and 50 µl Priming Solution, mix briefly (vortex) and incubate 10 min at ambient temperature.
  • Add 50 µl Internal Standard and mix briefly (vortex).
  • Centrifuge 10 min at 9000 x g.
  • Inject 25 µl supernatant into the HPLC system.
Run Time 20 min
Injection Volume 25 µl
Flow Rate 1.2 ml/min
Column Temperature +20 to +25 °C
Gradient binary
Wavelength EX 405 nm
EM 620 nm
Additional Info Any binary HPLC gradient system with fluorescence detector is suitable.
Parameters Vitamin A, Vitamin E

Vitamins A and E in Serum/Plasma - HPLC Basic Kit
For 200 sample preparations

Order No. Basic Kit components (Quantities in kit)
34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (1x)

 

Order No. Required components (not included in the Basic Kit)
34300 HPLC Column, equilibrated, with test chromatogram, 1 pc.
34001 Mobile Phase, 1000 ml
34004 Serum Calibration Standard, 5 x 1 ml (lyoph.)
0036 Serum Control, Level I, 5 x 2 ml (lyoph.)
0037 Serum Control, Level II, 5 x 2 ml (lyoph.)

 

Order No. General lab equipment (non-CE/IVD products)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs.
15070 Stainless Steel Prefilter Housing, 1 pc.
15012 PEEK-encased Prefilter, 0.5 µm,1 pc.
The following components are included in the kit:
The following products are not included in the kit but are required for the application of the method:
As a customer please login or register to gain full access.

Vitamin A

Vitamin E

Clinical relevance
This assay allows the quantitative determination of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III in human urine samples.
It is intended to be used for patients in whom the urinary levels of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III are of clinical importance, primarily as an aid to diagnosis of suspected acute intermittent porphyria, porphyria variegata, aminolevulinic acid dehydratase deficiency porphyria, hereditary coproporphyria, porphyria cutanea tarda or congenital erythropoietic porphyria and/or for their differential diagnosis.


Product advantages
• Easy sample preparation
• Stable standards and controls


Assay characteristics
Sample preparation consists of sample stabilisation, addition of the internal standard followed by centrifugation to separate particles that may be present in the urine. An oxidation step is not necessary as the porphyrinogens oxidise spontaneously by air into the fluorescent porphyrins. The internal standard elutes between the analytes thus avoiding analytical variation and inaccuracy as well as allowing a shortening of the chromatographic run time.

Detailed performance evaluation data for this assay can be found in Appendices II and III of the instruction manual.


Two types of kits available

Basic Kit
• Only sample preparation reagents and vials included
• No excess quantities of mobile phase and calibrators

34400-BK Basic Kit
For 200 sample preparations

   
   
34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (2x)

Reagent Kit
• Mobile phase and calibrator included

34400 Reagent Kit
For 200 tests

34001 Mobile Phase, 1000 ml (1x)
34004 Serum Calibration Standard, 5 x 1 ml (lyoph.) (1x)
34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (2x)
More Information
Method of Analysis HPLC
Sample Preparations 200
Please note The information listed here, including the sample preparation, is not sufficient for using the product. Please read the information provided in the instruction manual, which includes detailed information on limitations associated with the use of the product in line with its intended purpose. Detailed performance evaluation data for this assay can be found in Appendices II and III of the instruction manual.
Lower and Upper Limit of Quantitation

Uroporphyrin: 0.48 µg/l – 1400 µg/l
Heptacarboxyporphyrin: 0.84 µg/l – 3200 µg/l
Hexacarboxyporphyrin: 1.8 µg/l – 5000 µg/l
Pentacarboxyporphyrin: 0.90 µg/l – 4600 µg/l
Coproporphyrin I: 2.2 µg/l – 5000 µg/l
Coproporphyrin III: 2.6 µg/l – 5000 µg/l

Different systems might show different performance data.

Specimen Urine
Sample Preparation

The information on the sample preparation presented here is not sufficient for use in the laboratory. For a detailed step by step description, please refer to the instruction manual.

  • Pipette 500 µl sample/calibrator/control into an amber reaction vial.
  • Add 50 µl Stabilisation Reagent and 50 µl Priming Solution, mix briefly (vortex) and incubate 10 min at ambient temperature.
  • Add 50 µl Internal Standard and mix briefly (vortex).
  • Centrifuge 10 min at 9000 x g.
  • Inject 25 µl supernatant into the HPLC system.
Run Time 20 min
Injection Volume 25 µl
Flow Rate 1.2 ml/min
Column Temperature +20 to +25 °C
Gradient binary
Wavelength EX 405 nm
EM 620 nm
Additional Info Any binary HPLC gradient system with fluorescence detector is suitable.
Parameters Vitamin A, Vitamin E

Vitamins A and E in Serum/Plasma - HPLC Basic Kit
For 200 sample preparations

Order No. Basic Kit components (Quantities in kit)
34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (1x)

 

Order No. Required components (not included in the Basic Kit)
34300 HPLC Column, equilibrated, with test chromatogram, 1 pc.
34001 Mobile Phase, 1000 ml
34004 Serum Calibration Standard, 5 x 1 ml (lyoph.)
0036 Serum Control, Level I, 5 x 2 ml (lyoph.)
0037 Serum Control, Level II, 5 x 2 ml (lyoph.)

 

Order No. General lab equipment (non-CE/IVD products)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs.
15070 Stainless Steel Prefilter Housing, 1 pc.
15012 PEEK-encased Prefilter, 0.5 µm,1 pc.
The following components are included in the kit:
The following products are not included in the kit but are required for the application of the method: