Porphyrine im Urin - HPLC

Bestell-Nr.: 34400-BK
Parameter:
Vitamin A, Vitamin E

Einfache Probenvorbereitung
Stabile Standards und Kontrollen

Assay validiert nach IVDR (=> Konformitätserklärung)

Coproporphyrin I

Coproporphyrin III

Heptacarboxyporphyrin

Hexacarboxyporphyrin

Pentacarboxyporphyrin

Uroporphyrin

Clinical relevance
This assay allows the quantitative determination of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III in human urine samples.
It is intended to be used for patients in whom the urinary levels of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III are of clinical importance, primarily as an aid to diagnosis of suspected acute intermittent porphyria, porphyria variegata, aminolevulinic acid dehydratase deficiency porphyria, hereditary coproporphyria, porphyria cutanea tarda or congenital erythropoietic porphyria and/or for their differential diagnosis.

 

Product advantages
• Easy sample preparation
• Stable standards and controls

 

Assay characteristics
Sample preparation consists of sample stabilisation, addition of the internal standard followed by centrifugation to separate particles that may be present in the urine. An oxidation step is not necessary as the porphyrinogens oxidise spontaneously by air into the fluorescent porphyrins. The internal standard elutes between the analytes thus avoiding analytical variation and inaccuracy as well as allowing a shortening of the chromatographic run time.

Detailed performance evaluation data for this assay can be found in Appendices II and III of the instruction manual.

 

2 Types of kits available

1. Basic Kit for sample preparation
• Only sample preparation reagents and accessories included
• No excess quantities of mobile phase, calibrators (and rinsing solution)
• Flexibility in ordering – all components are available separately

34400-BK Basic Kit
For 200 sample preparations

34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (1x)

2. Reagent Kit
• Incl. mobile phase and calibrator
• Flexibility in ordering – all components are available separately

34400 Reagent Kit
For 200 tests

34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (1x)
34001 Mobile Phase, 1000 ml (1x)
34004 Serum Calibration Standard, 5 x 1 ml (lyoph.) (1x)
Weitere Informationen
Analysenmethode HPLC
Probenvorbereitungen 200
Hinweis Die hier aufgeführten Informationen einschließlich der Probenvorbereitung sind für die Verwendung des Produkts nicht ausreichend. Bitte lesen Sie die Angaben in der Arbeitsvorschrift. Dort befinden sich detaillierte Informationen zu Limitationen, die mit der Verwendung des Produkts gemäß seiner Zweckbestimmung verbunden sind. Detaillierte Daten zur Leistungsbewertung für diesen Assay finden Sie in den Anhängen II und III der Arbeitsvorschrift.
Untere und obere Bestimmungsgrenze

Uroporphyrin: 0,48 µg/l – 1400 µg/l
Heptacarboxyporphyrin: 0,84 µg/l – 3200 µg/l
Hexacarboxyporphyrin: 1,8 µg/l – 5000 µg/l
Pentacarboxyporphyrin: 0,90 µg/l – 4600 µg/l
Coproporphyrin I: 2,2 µg/l – 5000 µg/l
Coproporphyrin III: 2,6 µg/l – 5000 µg/l

Verschiedene Systeme können unterschiedliche Leistungsdaten aufweisen.

Probenmaterial Urin
Probenvorbereitung

Die hier aufgeführten Informationen zur Probenvorbereitung sind für die Verwendung im Labor nicht ausreichend. Eine detaillierte Schritt-für-Schritt-Beschreibung finden Sie in der Arbeitsvorschrift.

  • 500 µl Probe/Kalibrator/Kontrolle in einem bernsteinfarbenen Reaktionsgefäß vorlegen.
  • 50 µl Stabilisation Reagent und 50 µl Priming Solution zugeben, kurz mischen (Vortex) und 10 min bei Raumtemperatur inkubieren.
  • 50 µl Internal Standard zugeben und kurz mischen (Vortex).
  • 10 min bei 9000 x g zentrifugieren.
  • 25 µl Überstand in das HPLC-System injizieren.
Laufzeit 20 min
Injektionsvolumen 25 µl
Flussrate 1,2 ml/min
Säulentemperatur +20 bis +25 °C
Gradient binär
Messwellenlänge EX 405 nm
EM 620 nm
Zusätzliche Info Es eignet sich jedes gängige binäre HPLC-Gradientensystem mit Fluoreszenz-Detektor.
Parameter Vitamin A, Vitamin E

44000 Porphyrins in Urine
Für 100 Tests

Bestellnummer Kit-Komponenten (Mengen im Kit)
44001 Mobile Phase A, 1000 ml (2x)
44002 Mobile Phase B, 1000 ml (2x)
44003 Porphyrins Urine Calibration Standard (lyoph.), 5 x 2 ml (1x)
44004 Internal Standard, 5 ml (1x)
44005 Stabilisation Reagent, 5 ml (1x)
44006 Priming Solution, 5 ml (1x)
33005 Reaction Vials, amber coloured (light protection), 100 Stück (1x)

 

Bestellnummer Erforderliche Komponenten (nicht im Kit enthalten)
44100 HPLC Column, equilibrated, with test chromatogram, 1 Stück
0145 Porphyrins Urine Control, Level I, 5 x 2 ml
0146 Porphyrins Urine Control, Level II, 5 x 2 ml
18044 Precolumn Cartridge 4/10, 1 Stück

 

Bestellnummer Allgemeine Laborausrüstung (Nicht-CE/IVD-Produkte)
33005 Reaction Vials, amber coloured (light protection), 100 Stück (1x)
15010 PEEK Prefilter Housing, 1 Stück
15009 PEEK-encased Prefilter, 5 µm, 5 Stück
18001 Precolumn Cartridge Colder 4/10, 1 Stück
Die folgenden Produkte sind nicht im Kit enthalten, werden aber für die Anwendung der Methode benötigt:
Als Kunde können Sie sich für den kompletten Zugang bitte hier anmelden oder neu registrieren.

Coproporphyrin I

Coproporphyrin III

Heptacarboxyporphyrin

Hexacarboxyporphyrin

Pentacarboxyporphyrin

Uroporphyrin

Clinical relevance
This assay allows the quantitative determination of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III in human urine samples.
It is intended to be used for patients in whom the urinary levels of uroporphyrin, heptacarboxyporphyrin, hexacarboxyporphyrin, pentacarboxyporphyrin, coproporphyrin I and coproporphyrin III are of clinical importance, primarily as an aid to diagnosis of suspected acute intermittent porphyria, porphyria variegata, aminolevulinic acid dehydratase deficiency porphyria, hereditary coproporphyria, porphyria cutanea tarda or congenital erythropoietic porphyria and/or for their differential diagnosis.

 

Product advantages
• Easy sample preparation
• Stable standards and controls

 

Assay characteristics
Sample preparation consists of sample stabilisation, addition of the internal standard followed by centrifugation to separate particles that may be present in the urine. An oxidation step is not necessary as the porphyrinogens oxidise spontaneously by air into the fluorescent porphyrins. The internal standard elutes between the analytes thus avoiding analytical variation and inaccuracy as well as allowing a shortening of the chromatographic run time.

Detailed performance evaluation data for this assay can be found in Appendices II and III of the instruction manual.

 

2 Types of kits available

1. Basic Kit for sample preparation
• Only sample preparation reagents and accessories included
• No excess quantities of mobile phase, calibrators (and rinsing solution)
• Flexibility in ordering – all components are available separately

34400-BK Basic Kit
For 200 sample preparations

34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (1x)

2. Reagent Kit
• Incl. mobile phase and calibrator
• Flexibility in ordering – all components are available separately

34400 Reagent Kit
For 200 tests

34404 Internal Standard, 40 ml (1x)
34405 Precipitation Reagent, 40 ml (1x)
33005 Reaction Vials, 1.5 ml, amber coloured (light protection), 100 pcs. (1x)
34001 Mobile Phase, 1000 ml (1x)
34004 Serum Calibration Standard, 5 x 1 ml (lyoph.) (1x)
Weitere Informationen
Analysenmethode HPLC
Probenvorbereitungen 200
Hinweis Die hier aufgeführten Informationen einschließlich der Probenvorbereitung sind für die Verwendung des Produkts nicht ausreichend. Bitte lesen Sie die Angaben in der Arbeitsvorschrift. Dort befinden sich detaillierte Informationen zu Limitationen, die mit der Verwendung des Produkts gemäß seiner Zweckbestimmung verbunden sind. Detaillierte Daten zur Leistungsbewertung für diesen Assay finden Sie in den Anhängen II und III der Arbeitsvorschrift.
Untere und obere Bestimmungsgrenze

Uroporphyrin: 0,48 µg/l – 1400 µg/l
Heptacarboxyporphyrin: 0,84 µg/l – 3200 µg/l
Hexacarboxyporphyrin: 1,8 µg/l – 5000 µg/l
Pentacarboxyporphyrin: 0,90 µg/l – 4600 µg/l
Coproporphyrin I: 2,2 µg/l – 5000 µg/l
Coproporphyrin III: 2,6 µg/l – 5000 µg/l

Verschiedene Systeme können unterschiedliche Leistungsdaten aufweisen.

Probenmaterial Urin
Probenvorbereitung

Die hier aufgeführten Informationen zur Probenvorbereitung sind für die Verwendung im Labor nicht ausreichend. Eine detaillierte Schritt-für-Schritt-Beschreibung finden Sie in der Arbeitsvorschrift.

  • 500 µl Probe/Kalibrator/Kontrolle in einem bernsteinfarbenen Reaktionsgefäß vorlegen.
  • 50 µl Stabilisation Reagent und 50 µl Priming Solution zugeben, kurz mischen (Vortex) und 10 min bei Raumtemperatur inkubieren.
  • 50 µl Internal Standard zugeben und kurz mischen (Vortex).
  • 10 min bei 9000 x g zentrifugieren.
  • 25 µl Überstand in das HPLC-System injizieren.
Laufzeit 20 min
Injektionsvolumen 25 µl
Flussrate 1,2 ml/min
Säulentemperatur +20 bis +25 °C
Gradient binär
Messwellenlänge EX 405 nm
EM 620 nm
Zusätzliche Info Es eignet sich jedes gängige binäre HPLC-Gradientensystem mit Fluoreszenz-Detektor.
Parameter Vitamin A, Vitamin E

44000 Porphyrins in Urine
Für 100 Tests

Bestellnummer Kit-Komponenten (Mengen im Kit)
44001 Mobile Phase A, 1000 ml (2x)
44002 Mobile Phase B, 1000 ml (2x)
44003 Porphyrins Urine Calibration Standard (lyoph.), 5 x 2 ml (1x)
44004 Internal Standard, 5 ml (1x)
44005 Stabilisation Reagent, 5 ml (1x)
44006 Priming Solution, 5 ml (1x)
33005 Reaction Vials, amber coloured (light protection), 100 Stück (1x)

 

Bestellnummer Erforderliche Komponenten (nicht im Kit enthalten)
44100 HPLC Column, equilibrated, with test chromatogram, 1 Stück
0145 Porphyrins Urine Control, Level I, 5 x 2 ml
0146 Porphyrins Urine Control, Level II, 5 x 2 ml
18044 Precolumn Cartridge 4/10, 1 Stück

 

Bestellnummer Allgemeine Laborausrüstung (Nicht-CE/IVD-Produkte)
33005 Reaction Vials, amber coloured (light protection), 100 Stück (1x)
15010 PEEK Prefilter Housing, 1 Stück
15009 PEEK-encased Prefilter, 5 µm, 5 Stück
18001 Precolumn Cartridge Colder 4/10, 1 Stück
Die folgenden Produkte sind nicht im Kit enthalten, werden aber für die Anwendung der Methode benötigt:
Als Kunde können Sie sich für den kompletten Zugang bitte hier anmelden oder neu registrieren.