3PLUS1® Multilevel Plasma Calibrator Set Tricyclic Antidepressants TCA 2
Clomipramine
Norclomipramine
Maprotiline
Normaprotiline
Protriptyline
Trimipramine
Nortrimipramine
3PLUS1® Multilevel Plasma Calibrator Set Tricyclic Antidepressants TCA 2
For MassTox® TDM Series A Parameter Set Tricyclic Antidepressants TCA 2 in Serum/Plasma by LC-MS/MS (92920)
These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of tricyclic antidepressants TCA 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen. These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.
Content | 4 x 1 ml (lyoph.) | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Concentrations | Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login. NEW: An Excel file with the data from the product information leaflet is now available in the "Downloads" section (for registered customers only). This eliminates manual data entry of large data sets.
n.d. = not detected (< LOQ) The blank level is manufactured using the same matrix pool as used for the calibrator levels 1, 2 and 3. It was not fortified with any tricyclic antidepressants. |
||||||||||||||||||||||||||||||||||||||||
Storage conditions | Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored in glass containers up to 1 week light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual. |
||||||||||||||||||||||||||||||||||||||||
Method of Analysis | LC-MS/MS | ||||||||||||||||||||||||||||||||||||||||
Parameters | Clomipramine, Maprotiline, Norclomipramine, Normaprotiline, Nortrimipramine, Protriptyline, Trimipramine |
Clomipramine
Norclomipramine
Maprotiline
Normaprotiline
Protriptyline
Trimipramine
Nortrimipramine
3PLUS1® Multilevel Plasma Calibrator Set Tricyclic Antidepressants TCA 2
For MassTox® TDM Series A Parameter Set Tricyclic Antidepressants TCA 2 in Serum/Plasma by LC-MS/MS (92920)
These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of tricyclic antidepressants TCA 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen. These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.
Content | 4 x 1 ml (lyoph.) | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Concentrations | Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login. NEW: An Excel file with the data from the product information leaflet is now available in the "Downloads" section (for registered customers only). This eliminates manual data entry of large data sets.
n.d. = not detected (< LOQ) The blank level is manufactured using the same matrix pool as used for the calibrator levels 1, 2 and 3. It was not fortified with any tricyclic antidepressants. |
||||||||||||||||||||||||||||||||||||||||
Storage conditions | Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored in glass containers up to 1 week light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual. |
||||||||||||||||||||||||||||||||||||||||
Method of Analysis | LC-MS/MS | ||||||||||||||||||||||||||||||||||||||||
Parameters | Clomipramine, Maprotiline, Norclomipramine, Normaprotiline, Nortrimipramine, Protriptyline, Trimipramine |