6PLUS1® Multilevel Urine Calibrator Set VMA, HVA, 5-HIAA

Order No.: 80839
Parameters:
5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA)
MassChrom® Biogenic Amines/Metabolites in Urine – LC-MS/MS

6PLUS1® Multilevel Urine Calibrator Set VMA, HVA, 5-HIAA

For MassChrom® Biogenic Amines/Metabolites in Urine with Autosampler Vials or Collection Plates by LC-MS/MS (80800, 80800/96, 80800/480)

These lyophilised calibrators from Chromsystems are based on human urine and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of vanillylmandelic acid (VMA), homovanillic acid (HVA) and 5-hydroxyindole acetic acid (5-HIAA) in urine. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.

These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

More Information
Content 7 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

 
Substance UnitCalibrator 1Calibrator 2Calibrator 3Calibrator 4Calibrator 5Calibrator 6Blank Calibrator
VMA (Vanillylmandelic Acid) mg/l 
µmol/l
1.19
6.00
9.37
47.3
17.4
87.8
25.4
128
51.1
258
77.3
390
n.d.
HVA (Homovanillic Acid) mg/l 
µmol/l
0.869
4.77
11.8
64.8
23.4
128
34.7
190
79.9
439
119
653
n.d.
5-HIAA (5-Hydroxyindoleacetic Acid) mg/l 
µmol/l
0.699
3.66
2.51
13.1
4.55
23.8
6.44
33.7
37.2
195
68.0
356
n.d.

n.d. = not determined (< LOQ)

Storage conditions

Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 4 weeks light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

Method of Analysis LC-MS/MS
Parameters 5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA)
As a customer please login or register to gain full access.

6PLUS1® Multilevel Urine Calibrator Set VMA, HVA, 5-HIAA

For MassChrom® Biogenic Amines/Metabolites in Urine with Autosampler Vials or Collection Plates by LC-MS/MS (80800, 80800/96, 80800/480)

These lyophilised calibrators from Chromsystems are based on human urine and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of vanillylmandelic acid (VMA), homovanillic acid (HVA) and 5-hydroxyindole acetic acid (5-HIAA) in urine. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.

These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

More Information
Content 7 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

 
Substance UnitCalibrator 1Calibrator 2Calibrator 3Calibrator 4Calibrator 5Calibrator 6Blank Calibrator
VMA (Vanillylmandelic Acid) mg/l 
µmol/l
1.19
6.00
9.37
47.3
17.4
87.8
25.4
128
51.1
258
77.3
390
n.d.
HVA (Homovanillic Acid) mg/l 
µmol/l
0.869
4.77
11.8
64.8
23.4
128
34.7
190
79.9
439
119
653
n.d.
5-HIAA (5-Hydroxyindoleacetic Acid) mg/l 
µmol/l
0.699
3.66
2.51
13.1
4.55
23.8
6.44
33.7
37.2
195
68.0
356
n.d.

n.d. = not determined (< LOQ)

Storage conditions

Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 4 weeks light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

Method of Analysis LC-MS/MS
Parameters 5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA)
As a customer please login or register to gain full access.