Plasma Calibration Standard

Order No.: 5009
Parameters:
Adrenaline (Epinephrine), Dopamine, Noradrenaline (Norepinephrine)
Catecholamines in Plasma - HPLC

Plasma Calibration Standard for Catecholamines in Plasma, lyophilised

This lyophilised calibrator (order no. 5009) from Chromsystems is based on human plasma and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of catecholamines in plasma. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.
An alternative is the aqueous calibration standard (order no. 5003) that is directly injected into the HPLC system without sample preparation.

More Information
Content 10 x 2.5 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitPlasma Calibration Standard
Noradrenaline ng/l
pmol/l
1135
6710
Adrenaline ng/l
pmol/l
302
1646
Dopamine ng/l
pmol/l
406
2650
Storage conditions

Stored at +2 to +8 °C and unopened, the lyophilised calibrator is stable until the expiry date specified on the vial labels. The reconstituted calibrator can be stored up to 2 days tightly capped at +2 to +8 C. If the calibrator cannot be used within this period, it should be aliquoted and stored frozen below -18 °C (up to 2 months). For more details about storage conditions please check your instruction manual.

Method of Analysis HPLC
Parameters Adrenaline (Epinephrine), Dopamine, Noradrenaline (Norepinephrine)
As a customer please login or register to gain full access.

Plasma Calibration Standard for Catecholamines in Plasma, lyophilised

This lyophilised calibrator (order no. 5009) from Chromsystems is based on human plasma and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of catecholamines in plasma. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.
An alternative is the aqueous calibration standard (order no. 5003) that is directly injected into the HPLC system without sample preparation.

More Information
Content 10 x 2.5 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitPlasma Calibration Standard
Noradrenaline ng/l
pmol/l
1135
6710
Adrenaline ng/l
pmol/l
302
1646
Dopamine ng/l
pmol/l
406
2650
Storage conditions

Stored at +2 to +8 °C and unopened, the lyophilised calibrator is stable until the expiry date specified on the vial labels. The reconstituted calibrator can be stored up to 2 days tightly capped at +2 to +8 C. If the calibrator cannot be used within this period, it should be aliquoted and stored frozen below -18 °C (up to 2 months). For more details about storage conditions please check your instruction manual.