t,t-Muconic Acid Urine Controls

Order No.: 0161/0162/0163
Parameters:
t,t-Muconic Acid
Grouped product items
Product Name Qty
t,t-Muconic Acid Urine Control, Level I
Order No.: 0162
t,t-Muconic Acid Urine Control, Level II
Order No.: 0163
t,t-Muconic Acid Urine Control, Bi-Level (I+II)
Order No.: 0161

t,t-Muconic Acid Urine Controls, lyophilised

0161 t,t-Muconic Acid Urine Control, Bi-Level I + II (lyoph.), 2 x 5 x 2 ml
0162 t,t-Muconic Acid Urine Control, Level I (lyoph.), 5 x 2 ml
0163 t,t-Muconic Acid Urine Control, Level II (lyoph.), 5 x 2 ml

These lyophilised Chromsystems quality controls are based on human urine and should be used according to the instruction manual. They are designed to monitor the accuracy and precision of analytical procedures in clinical diagnostics for the quantitative determination of t,t-muconic acidin urine. While following the instructions the controls should be handled and injected in the same manner as a patient specimen.

More Information
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitValue Level IRange Level IValue Level IIRange Level II
t,t-Muconic Acid mg/l
µmol/l
0.82
5.78
0.66-0.99
4.62-6.93
2.62
18.5
2.10-3.15
14.8-22.2
Storage conditions

Stored below -18 °C and unopened, the lyophilised controls are stable until the expiry date specified on the vial labels. The reconstituted controls can be stored up to 2 weeks tightly capped at +2 to +8 C. The prepared control sample has the same stability as a fresh urine specimen. If the controls cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

Method of Analysis HPLC
Parameters t,t-Muconic Acid
As a customer please login or register to gain full access.

t,t-Muconic Acid Urine Controls, lyophilised

0161 t,t-Muconic Acid Urine Control, Bi-Level I + II (lyoph.), 2 x 5 x 2 ml
0162 t,t-Muconic Acid Urine Control, Level I (lyoph.), 5 x 2 ml
0163 t,t-Muconic Acid Urine Control, Level II (lyoph.), 5 x 2 ml

These lyophilised Chromsystems quality controls are based on human urine and should be used according to the instruction manual. They are designed to monitor the accuracy and precision of analytical procedures in clinical diagnostics for the quantitative determination of t,t-muconic acidin urine. While following the instructions the controls should be handled and injected in the same manner as a patient specimen.

More Information
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitValue Level IRange Level IValue Level IIRange Level II
t,t-Muconic Acid mg/l
µmol/l
0.82
5.78
0.66-0.99
4.62-6.93
2.62
18.5
2.10-3.15
14.8-22.2
Storage conditions

Stored below -18 °C and unopened, the lyophilised controls are stable until the expiry date specified on the vial labels. The reconstituted controls can be stored up to 2 weeks tightly capped at +2 to +8 C. The prepared control sample has the same stability as a fresh urine specimen. If the controls cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

Method of Analysis HPLC
Parameters t,t-Muconic Acid