Urine Calibration Standard
Calibration Standard for Serotonin in urine, lyophilised
This lyophilised calibrator (order no. 4009) from Chromsystems is based on human urine and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of serotonin in urine. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.
An alternative is the aqueous calibration standard (order no. 3003) that is directly injected into the HPLC system without sample preparation.
Content | 5 x 12 ml (lyoph.) | ||||||
---|---|---|---|---|---|---|---|
Concentrations | Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.
|
||||||
Storage conditions | Stored at +2 to +8 °C and unopened, the lyophilised calibrator is stable until the expiry date specified on the vial labels. The reconstituted calibrator can be stored up to 5 days tightly capped at +2 to +8 C. If the calibrator cannot be used within this period, it should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual. |
||||||
Method of Analysis | HPLC | ||||||
Parameters | Serotonin |
Calibration Standard for Serotonin in urine, lyophilised
This lyophilised calibrator (order no. 4009) from Chromsystems is based on human urine and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of serotonin in urine. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.
An alternative is the aqueous calibration standard (order no. 3003) that is directly injected into the HPLC system without sample preparation.
Content | 5 x 12 ml (lyoph.) | ||||||
---|---|---|---|---|---|---|---|
Concentrations | Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.
|
||||||
Storage conditions | Stored at +2 to +8 °C and unopened, the lyophilised calibrator is stable until the expiry date specified on the vial labels. The reconstituted calibrator can be stored up to 5 days tightly capped at +2 to +8 C. If the calibrator cannot be used within this period, it should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual. |
||||||
Method of Analysis | HPLC | ||||||
Parameters | Serotonin |