3PLUS1® Multilevel Plasma Calibrator Set Methylmalonic Acid

Order No.: 64028
Parameters:
Methylmalonic Acid (MMA)
MassChrom® Methylmalonic Acid in Plasma/Serum and Urine – LC-MS/MS

3PLUS1® Multilevel Plasma Calibrator Set Methylmalonic Acid, lyophilised

For MassChrom® Methylmalonic Acid in Plasma/Serum and Urine by LC-MS/MS (64000)

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of methylmalonic acid in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

More Information
Content 4 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login. 

SubstanceUnitCalibrator 1Calibrator 2Calibrator 3Low level Calibrator
Methylmalonic Acid µg/l
nmol/l
11
97
82
690
180
1525
4
31
Storage conditions

Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 2 weeks light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 2 months). For more details about storage conditions please check your instruction manual.

Method of Analysis LC-MS/MS
Parameters Methylmalonic Acid (MMA)
As a customer please login or register to gain full access.

3PLUS1® Multilevel Plasma Calibrator Set Methylmalonic Acid, lyophilised

For MassChrom® Methylmalonic Acid in Plasma/Serum and Urine by LC-MS/MS (64000)

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of methylmalonic acid in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

More Information
Content 4 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login. 

SubstanceUnitCalibrator 1Calibrator 2Calibrator 3Low level Calibrator
Methylmalonic Acid µg/l
nmol/l
11
97
82
690
180
1525
4
31
Storage conditions

Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 2 weeks light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 2 months). For more details about storage conditions please check your instruction manual.